Smart temperature transmitter

Specification:

InputTypeMeasurement RangesMin. Measurement SpanMeasurement Accuracy
Resistance Thermometer (RTD)Pt100-200°C to 850°C10°K0.1°C
Pt500-200°C to 250°C10°K
Pt1000-200°C to 250°C10°K
Cu50-50°C to 150°C10°K
Cu100-50°C to 150°C10°K
*Ni100-60°C to 180°C10°K
*Ni500-60°C to 180°C10°K
*Ni1000-60°C to 150°C10°K
Resistance TransmitterResistance (Ω)0 Ω to 400 Ω10 Ω±0.1 Ω or 0.075%
0 Ω to 2000 Ω100 Ω±1.5 Ω or 0.12%
Thermocouples (TC)B (PtRh30-PtRh6)0 to 1820°C500°KTyp. 1°C
E (NiCr-CuNi)-270°C to 1000°C50°K0.5°C
J (Fe-CuNi)-210°C to 1200°C50°K
K (NiCr-Ni)-270°C to 1372°C50°K
N (NiCrSi-NiSi)-270°C to 1300°C50°K
R (PtRh13-Pt)-50°C to 1768°C500°K1°C
S (PtRh10-Pt)-50°C to 1768°C500°K
T (Cu-CuNi)-270°C to 400°C50°K0.5°C
Voltage Transmitters (mV)Millivolt Transmitter (mV)-10 to 75mV5mV0.10%
-100 to 100mV5mV
-100 to 500mV6mV
-100 to 200mV20mV
OUTPUT SPECIFICATIONS
Output4 to 20mA
Signal on AlarmUnder RangingLinear Drop to 3.8mA
Over RangingLinear Rise to 20.5mA
Sensor break/ Open circuit3.6mA (Downscale) or 22mA (Upscale), selectable
LoadMax. (V(Power Supply) – 10.5V)/ 0.022A
Linearisation/ Transmission BehaviourTemperature Linear (RTD/ T/C), Linear (Resistance or voltage inputs)
Galvanic Isolation1 KV AC (input/ output), Galvanic
Communiation InterfaceHART Protocol (TTFUH) or PROFIBUS – PA Protocol (TTFUP)
PERFORMACE CHARACTERSTICS
Response Time1sec
Reference Operating ConditionCalibration temperature: 23°C ± 5K
Long Term Stability0.01°C (RTD), 0.1° (E,J,K,N,T), 0.2°C (B,R,S)
Switch on Delay≤ 5s
Influence of AmbientNegligible
Filter Configuration0 to 160µA
Resolution0.3µA
ENVIRONMENT CONDITION
Ambent Temperature Limits-20°C to 70°C
Storage Temperature-20°C to 70°C
CondensationAllowable
Degree of ProtectionIP65
Shock and Vibration Resistance4g/2 to 150Hz as per IEC 60 068-26
Electromagnetic Compatibility (EMC)Interference immunity and interference emission according to GB/ T17626.2-1998), compliance with IEC 61000-4-3: 1995
OTHERS
Display TypeVisible range 32.5×22.5mm; 5 digit, 7 segment main display, digit height 8mm; 20bars meter with 5% resolution
Display Range-19999 – 99999
EnclosureDual chamber (terminals on one side & display on other) – standard single chamber (terminals below plugin display) – put suffix “S” after model number example TTFUHS
Weight/ MaterialApprox. 800G/ Die-cast Aluminium
Power Supply9 to 32VDC, Polarity Protected