TEMPERATURE TRANSMITTERS- Temperature transmitter without display

Specification           

Input Type Measurement Ranges Min. Measurement Span Measurement Accuracy
Resistance Thermometer (RTD) 2/3/4 Wire Pt100 -200°C to 850°C 10°K 0.2K or 0.075%
Pt500 -70°C to 500°C 10°K 0.5K or 0.20%
Pt1000 -70°C to 500°C 10°K 0.3K or 0.12%
Pt50 -200°C to 850°C 10°K 0.2K or 0.075%
Resistance Transmitter, 2/3/4 Wire Resistance (Ω) 0 Ω to 500 Ω 10 Ω ±0.1 Ω or 0.075%
0 Ω to 4500 Ω 100 Ω ±1.5 Ω or 0.12%
Thermocouples (TC) B (PtRh30-PtRh6) 0 to 1820°C 100°K Typ. 2.0K or 0.075%
E (NiCr-CuNi) -270°C to 1000°C 25°K Typ. 0.5K or 0.075%
J (Fe-CuNi) -210°C to 1200°C 25°K Typ. 0.5K or 0.075%
K (NiCr-Ni) -270°C to 1372°C 25°K Typ. 0.5K or 0.075%
N (NiCrSi-NiSi) -270°C to 1300°C 25°K Typ. 1.0K or 0.075%
R (PtRh13-Pt) -50°C to 1768°C 100°K Typ. 2.0K or 0.075%
S (PtRh10-Pt) -50°C to 1768°C 100°K Typ. 2.0K or 0.075%
T (Cu-CuNi) -270°C to 400°C 50°K Typ. 0.5K or 0.075%
Voltage Transmitters (mV) Millivolt Transmitter (mV) -120 to 120mV 5mV ±20µV or 0.075%
-1000 to 1000mV 20mV ±50µV or 0.075%
OUTPUT SPECIFICATIONS
Output 4 to 20mA
Signal on Alarm Under Ranging Linear Drop to 3.9mA
Over Ranging Linear Rise to 21mA
Sensor break/ Open circuit 3.9mA
Load Max. (V(Power Supply) – 7.5V)/ 0.022A
Linearisation/ Transmission Behaviour Temperature Linear (RTD/ T/C inputs), Linear (Resistance or voltage inputs)
Galvanic Isolation 2 KV AC (input/ output) (Except TTHRN, TTHUN)
Communiation Interface Through USB/ HART Communication accessory
PERFORMACE CHARACTERSTICS
Response Time < 1sec
Reference Operation Condition Calibration temperature: 27°C ± 5K
Long Term Stability ≤ 0.05%/ year
Switch on Delay ≤ 5s
Influence of Ambient Negligible
Load Influence Negligible
Power Supply Influence Negligible
Filter Setting 0 to 32s
Resolution 0.3µA
ENVIRONMENT CONDITION
Ambent Temperature Limits -40°C to 85°C
Storage Temperature -40°C to 100°C
Condensation Allowable
Degree of Protection Ip00 (Without enclosure)/ IP65 (With enclosure)
Shock and Vibration Resistance 4g/2 to 150Hz as per IEC 60 068-26
Electromagnetic Compatibility (EMC) Interference immunity and interference emission according to GB/ T17626.2-1998), compliance with IEC 61000-4-3: 1995
OTHERS
Dimensions

Sensor Head Mounting

DIN Rail Mounting

IP65 Enclosure

 

Dia 44mm x 24.7mm

115 x 100 x 22mm

115 x 155 x 120

Material

Sensor head/ DIN rail mounting

Housing: Polycarbonate; Potting: epoxy

Housing: Cast Aluminium

Power Supply 10 to 32VDC